Split System
R32 efficiently works even in small volume compared to existing R410A refrigerant, which decreases the potential hazard of globalwarming. Furthermore, R32 refrigerant is easy to recycle thanks toits single composition.
Features:
R32 Gas-Low GWP
Split heat pump for home heating
Climate curves suitable for different countries
House heating,cooling and domestic hot water
Inverter heat pump for home heating/cooling and DHW
Good SCOP,energy label rating W35℃ A+++/ W55℃ A++.
R32 environmental refrigerant
Wotech is a pioneer in launching heat pumps equipped with R32. With a lower Global Warming Potential (GWP), the R32 is equivalent in power to standardrefrigerants, but achieves higher energy efficiency and lower CO2, emissions.Easy to recover and reuse, R32 is the perfect solution for attaining the new European CO2, emission targets.
ENERGY EFFICIENCY RATING LABEL
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
MITSUBISHI Compressor
we choose MITSUBISHI compressor for the heat pump. It ensures stable working in the perfect performance.
Split Series Application Diagram
Contributing to a descarbonised society
The heat pump is considered a "green' choice as the heat energy is taken from the environment, making it a sustainable option.
*It maintains a comfortable indoor temperature while significantly reducing environmental burden.
*Wote R32 air to water Heat Pumps can also be connected to an e-heater, gas boiler, solar thermal or Py system in order to increase efficiency and minimise environmental impact.
Climate curve
Using proprietary Heating Curve Logic, users can set up the system to meet their optimum comfort levels based on the changing heat demand,insulation levels, etc Wotech air to water heat pump can adjust the outlet water temperatures based on the ambient temperature,by continually monitoring and adjusting it in opposite direction with the current ambient temperature levels to ensure the optimum comfort in the living spaces.
Wifi App control
Easily control your climate remotely from virtually anywhere using your smartphone or tablet. Download the application for free via the App Store and achieve optimal temperature conditions with great energy savings.
Split System
R32 efficiently works even in small volume compared to existing R410A refrigerant, which decreases the potential hazard of globalwarming. Furthermore, R32 refrigerant is easy to recycle thanks toits single composition.
Features:
R32 Gas-Low GWP
Split heat pump for home heating
Climate curves suitable for different countries
House heating,cooling and domestic hot water
Inverter heat pump for home heating/cooling and DHW
Good SCOP,energy label rating W35℃ A+++/ W55℃ A++.
R32 environmental refrigerant
Wotech is a pioneer in launching heat pumps equipped with R32. With a lower Global Warming Potential (GWP), the R32 is equivalent in power to standardrefrigerants, but achieves higher energy efficiency and lower CO2, emissions.Easy to recover and reuse, R32 is the perfect solution for attaining the new European CO2, emission targets.
ENERGY EFFICIENCY RATING LABEL
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
MITSUBISHI Compressor
we choose MITSUBISHI compressor for the heat pump. It ensures stable working in the perfect performance.
Split Series Application Diagram
Contributing to a descarbonised society
The heat pump is considered a "green' choice as the heat energy is taken from the environment, making it a sustainable option.
*It maintains a comfortable indoor temperature while significantly reducing environmental burden.
*Wote R32 air to water Heat Pumps can also be connected to an e-heater, gas boiler, solar thermal or Py system in order to increase efficiency and minimise environmental impact.
Climate curve
Using proprietary Heating Curve Logic, users can set up the system to meet their optimum comfort levels based on the changing heat demand,insulation levels, etc Wotech air to water heat pump can adjust the outlet water temperatures based on the ambient temperature,by continually monitoring and adjusting it in opposite direction with the current ambient temperature levels to ensure the optimum comfort in the living spaces.
Wifi App control
Easily control your climate remotely from virtually anywhere using your smartphone or tablet. Download the application for free via the App Store and achieve optimal temperature conditions with great energy savings.
Market model | WW08VM-O | WW12VM-O | WW16VM-O | WW20VT-O | |||||
Heating | Output Capacity | Kw | 3.23-8.20 | 4.78-12.13 | 6.58-16.71 | 8.14-20.67 | |||
Input Power | Kw | 0.58-1.75 | 0.89-2.75 | 1.21-3.72 | 1.45-4.24 | ||||
COP | - | 4.68-5.62 | 4.42-5.35 | 4.49-5.43 | 4.87-5.60 | ||||
Input Current | A | 2.63-8.01 | 4.09-12.59 | 5.54-17.03 | 2.47-7.21 | ||||
Heating | Output Capacity | Kw | 2.73-7.19 | 4.16-10.94 | 5.54-14.57 | 7.41-19.50 | |||
Input Power | Kw | 0.96-2.51 | 1.35-4.19 | 1.68-5.20 | 1.95-6.06 | ||||
COP | - | 2.86-3.37 | 2.61-3.08 | 2.80-3.30 | 3.22-3.80 | ||||
Input Current | A | 4.37-11.50 | 6.18-19.18 | 7.67-23.81 | 3.32-10.30 | ||||
Heating | Output Capacity | Kw | 3.88-9.84 | 5.73-14.56 | 7.90-20.05 | 9.77-24.80 | |||
Input Power | Kw | 0.80-2.23 | 1.23-3.42 | 1.69-4.71 | 2.04-5.70 | ||||
COP | - | 4.42-4.86 | 4.25-4.68 | 4.26-4.69 | 4.35-4.79 | ||||
Input Current | A | 3.65-10.19 | 5.61-15.67 | 7.71-21.54 | 3.47-9.70 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 2.74-6.53 | 4.07-9.70 | 5.28-12.58 | 6.57-15.65 | |||
Input Power | Kw | 0.88-2.48 | 1.30-3.66 | 1.59-4.48 | 1.99-5.20 | ||||
EER | - | 2.63-3.10 | 2.65-3.13 | 2.81-3.32 | 3.01-3.31 | ||||
Input Current | A | 4.04-11.35 | 5.96-16.75 | 7.29-20.49 | 3.38-8.84 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R32 | |||||||
Max Water Temperature(without backup heater) | ºC | 60 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | outdoor unit | dB(A) | 50 | 52 | 56 | 58 | |||
indoor unit | 27 | 27 | 27 | 27 | |||||
Net Dimension (L*W*H) | outdoor unit | mm | 1070*410*840 | 1070*410*960 | 1070*410*960 | 1150*430*1400 | |||
indoor unit | 475*220*800 | 475*220*800 | 475*220*800 | 475*220*800 |
Market model | WW08VM-O | WW12VM-O | WW16VM-O | WW20VT-O | |||||
Heating | Output Capacity | Kw | 3.23-8.20 | 4.78-12.13 | 6.58-16.71 | 8.14-20.67 | |||
Input Power | Kw | 0.58-1.75 | 0.89-2.75 | 1.21-3.72 | 1.45-4.24 | ||||
COP | - | 4.68-5.62 | 4.42-5.35 | 4.49-5.43 | 4.87-5.60 | ||||
Input Current | A | 2.63-8.01 | 4.09-12.59 | 5.54-17.03 | 2.47-7.21 | ||||
Heating | Output Capacity | Kw | 2.73-7.19 | 4.16-10.94 | 5.54-14.57 | 7.41-19.50 | |||
Input Power | Kw | 0.96-2.51 | 1.35-4.19 | 1.68-5.20 | 1.95-6.06 | ||||
COP | - | 2.86-3.37 | 2.61-3.08 | 2.80-3.30 | 3.22-3.80 | ||||
Input Current | A | 4.37-11.50 | 6.18-19.18 | 7.67-23.81 | 3.32-10.30 | ||||
Heating | Output Capacity | Kw | 3.88-9.84 | 5.73-14.56 | 7.90-20.05 | 9.77-24.80 | |||
Input Power | Kw | 0.80-2.23 | 1.23-3.42 | 1.69-4.71 | 2.04-5.70 | ||||
COP | - | 4.42-4.86 | 4.25-4.68 | 4.26-4.69 | 4.35-4.79 | ||||
Input Current | A | 3.65-10.19 | 5.61-15.67 | 7.71-21.54 | 3.47-9.70 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 2.74-6.53 | 4.07-9.70 | 5.28-12.58 | 6.57-15.65 | |||
Input Power | Kw | 0.88-2.48 | 1.30-3.66 | 1.59-4.48 | 1.99-5.20 | ||||
EER | - | 2.63-3.10 | 2.65-3.13 | 2.81-3.32 | 3.01-3.31 | ||||
Input Current | A | 4.04-11.35 | 5.96-16.75 | 7.29-20.49 | 3.38-8.84 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R32 | |||||||
Max Water Temperature(without backup heater) | ºC | 60 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | outdoor unit | dB(A) | 50 | 52 | 56 | 58 | |||
indoor unit | 27 | 27 | 27 | 27 | |||||
Net Dimension (L*W*H) | outdoor unit | mm | 1070*410*840 | 1070*410*960 | 1070*410*960 | 1150*430*1400 | |||
indoor unit | 475*220*800 | 475*220*800 | 475*220*800 | 475*220*800 |