Monoblock system:
Wotech provides the monoblock heat pump with main circulation pump built inside. When installing the unit, installer should connect the heat pump with other parts including the buffer tank (for space heating/cooling), storage water tank (for domestic hot water) and water pumps (for space heating/cooling water circulation and domestic hot water). External fittings are also needed in cluding the safety valve, water refill valve and hot water valves (three-way valve).Temperature sensor should be added in the storage water tank. Additional electric heater can be installed in the DHW tank or the buffer tank which can getthe control signal from the heat pump.
Features:
Wotech R32 Air to Water Heat Pump is specially developed with the most cutting-edge heat pump technology and modern design to meet stringent requirements for efficiency, stability and quietness. Not only does it use R32 green gas and inverter technology, but it is also rated with the A++ energy label. With a top energy rating of A+++, the unit is energy efficient and can significantly reduce the user's energy bill.
R32 environmental refrigerant
R32 has a GWP of 675, roughly 30% lower than that of R410A
R32 systems use up to 20% less refrigerant than R4|0A, making them more efficient and cost less to operate
Ozone Depletion Potential of 0
Easier to recycle than R410A, as R32 is a single component refrigerant
ENERGY EFFICIENCY RATING LABEL
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
We choose MITSUBISHI compressor for the heat pump. It ensures stable working in the perfect performance.
Two heating circuits [as standard]
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
Application with multiple heat source
Smart design to work with other heating facilities in your house, like solar, gas boiler and etc, make sure you to pay the lowest bill for heating !
DHW tank disinfection
The water inside the HWT (hot water tank) must be periodically heated to temperatures over 65°C to eliminate bacterial growth inside the tank if domestic hot water is provided directly from the tank.For healthy living, Wotech air source heat pump automatically controls this function based on parameter settings.
Climate curve
Using proprietary Heating Curve Logic, users can set up the system to meet their optimum comfort levels based on the changing heat demand,insulation levels, etc Wotech air to water heat pump can adjust the outlet water temperatures based on the ambient temperature,by continually monitoring and adjusting it in opposite direction with the current ambient temperature levels to ensure the optimum comfort in the living spaces.
Floor preheating and drying
With Floor Preheating, you can avoid potential floor damage and smoothly transition from the preheating to the heating function, avoiding any floor damage.In addition to protecting the installation, the Floor Drying Up function ensures the heat pump operates optimally and effectively by removing any residual moisture from newly installed floor coils.
Monoblock system:
Wotech provides the monoblock heat pump with main circulation pump built inside. When installing the unit, installer should connect the heat pump with other parts including the buffer tank (for space heating/cooling), storage water tank (for domestic hot water) and water pumps (for space heating/cooling water circulation and domestic hot water). External fittings are also needed in cluding the safety valve, water refill valve and hot water valves (three-way valve).Temperature sensor should be added in the storage water tank. Additional electric heater can be installed in the DHW tank or the buffer tank which can getthe control signal from the heat pump.
Features:
Wotech R32 Air to Water Heat Pump is specially developed with the most cutting-edge heat pump technology and modern design to meet stringent requirements for efficiency, stability and quietness. Not only does it use R32 green gas and inverter technology, but it is also rated with the A++ energy label. With a top energy rating of A+++, the unit is energy efficient and can significantly reduce the user's energy bill.
R32 environmental refrigerant
R32 has a GWP of 675, roughly 30% lower than that of R410A
R32 systems use up to 20% less refrigerant than R4|0A, making them more efficient and cost less to operate
Ozone Depletion Potential of 0
Easier to recycle than R410A, as R32 is a single component refrigerant
ENERGY EFFICIENCY RATING LABEL
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
We choose MITSUBISHI compressor for the heat pump. It ensures stable working in the perfect performance.
Two heating circuits [as standard]
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
Application with multiple heat source
Smart design to work with other heating facilities in your house, like solar, gas boiler and etc, make sure you to pay the lowest bill for heating !
DHW tank disinfection
The water inside the HWT (hot water tank) must be periodically heated to temperatures over 65°C to eliminate bacterial growth inside the tank if domestic hot water is provided directly from the tank.For healthy living, Wotech air source heat pump automatically controls this function based on parameter settings.
Climate curve
Using proprietary Heating Curve Logic, users can set up the system to meet their optimum comfort levels based on the changing heat demand,insulation levels, etc Wotech air to water heat pump can adjust the outlet water temperatures based on the ambient temperature,by continually monitoring and adjusting it in opposite direction with the current ambient temperature levels to ensure the optimum comfort in the living spaces.
Floor preheating and drying
With Floor Preheating, you can avoid potential floor damage and smoothly transition from the preheating to the heating function, avoiding any floor damage.In addition to protecting the installation, the Floor Drying Up function ensures the heat pump operates optimally and effectively by removing any residual moisture from newly installed floor coils.
Market model | WW08VM | WW12VM | WW16VM | WW20VT | |||||
Heating | Output Capacity | Kw | 4.78-12.13 | 4.78-12.13 | 6.58-16.71 | 8.14-20.67 | |||
Input Power | Kw | 0.58-1.75 | 0.89-2.75 | 1.21-3.72 | 1.45-4.24 | ||||
COP | - | 4.68-5.62 | 4.42-5.35 | 4.49-5.43 | 4.87-5.60 | ||||
Input Current | A | 2.63-8.01 | 4.09-12.59 | 5.54-17.03 | 2.47-7.21 | ||||
Heating | Output Capacity | Kw | 2.73-7.19 | 4.16-10.94 | 5.54-14.57 | 7.41-19.50 | |||
Input Power | Kw | 0.96-2.51 | 1.35-4.19 | 1.68-5.20 | 1.95-6.06 | ||||
COP | - | 2.86-3.37 | 2.61-3.08 | 2.80-3.30 | 3.22-3.80 | ||||
Input Current | A | 4.37-11.50 | 6.18-19.18 | 7.67-23.81 | 3.32-10.30 | ||||
Heating | Output Capacity | Kw | 3.88-9.84 | 5.73-14.56 | 7.90-20.05 | 9.77-24.80 | |||
Input Power | Kw | 0.80-2.23 | 1.23-3.42 | 1.69-4.71 | 2.04-5.70 | ||||
COP | - | 4.42-4.86 | 4.25-4.68 | 4.26-4.69 | 4.35-4.79 | ||||
Input Current | A | 3.65-10.19 | 5.61-15.67 | 7.71-21.54 | 3.47-9.70 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 2.74-6.53 | 4.07-9.70 | 5.28-12.58 | 6.57-15.65 | |||
Input Power | Kw | 0.88-2.48 | 1.30-3.66 | 1.59-4.48 | 1.99-5.20 | ||||
EER | - | 2.63-3.10 | 2.65-3.13 | 2.81-3.32 | 3.01-3.31 | ||||
Input Current | A | 4.04-11.35 | 5.96-16.75 | 7.29-20.49 | 3.38-8.84 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R32 | |||||||
Max Water Temperature(without backup heater) | ºC | 60 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 50 | 52 | 56 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*410*840 | 1150*430*960 | 1150*430*960 | 1150*430*1400 |
Market model | WW08VM | WW12VM | WW16VM | WW20VT | |||||
Heating | Output Capacity | Kw | 4.78-12.13 | 4.78-12.13 | 6.58-16.71 | 8.14-20.67 | |||
Input Power | Kw | 0.58-1.75 | 0.89-2.75 | 1.21-3.72 | 1.45-4.24 | ||||
COP | - | 4.68-5.62 | 4.42-5.35 | 4.49-5.43 | 4.87-5.60 | ||||
Input Current | A | 2.63-8.01 | 4.09-12.59 | 5.54-17.03 | 2.47-7.21 | ||||
Heating | Output Capacity | Kw | 2.73-7.19 | 4.16-10.94 | 5.54-14.57 | 7.41-19.50 | |||
Input Power | Kw | 0.96-2.51 | 1.35-4.19 | 1.68-5.20 | 1.95-6.06 | ||||
COP | - | 2.86-3.37 | 2.61-3.08 | 2.80-3.30 | 3.22-3.80 | ||||
Input Current | A | 4.37-11.50 | 6.18-19.18 | 7.67-23.81 | 3.32-10.30 | ||||
Heating | Output Capacity | Kw | 3.88-9.84 | 5.73-14.56 | 7.90-20.05 | 9.77-24.80 | |||
Input Power | Kw | 0.80-2.23 | 1.23-3.42 | 1.69-4.71 | 2.04-5.70 | ||||
COP | - | 4.42-4.86 | 4.25-4.68 | 4.26-4.69 | 4.35-4.79 | ||||
Input Current | A | 3.65-10.19 | 5.61-15.67 | 7.71-21.54 | 3.47-9.70 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 2.74-6.53 | 4.07-9.70 | 5.28-12.58 | 6.57-15.65 | |||
Input Power | Kw | 0.88-2.48 | 1.30-3.66 | 1.59-4.48 | 1.99-5.20 | ||||
EER | - | 2.63-3.10 | 2.65-3.13 | 2.81-3.32 | 3.01-3.31 | ||||
Input Current | A | 4.04-11.35 | 5.96-16.75 | 7.29-20.49 | 3.38-8.84 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R32 | |||||||
Max Water Temperature(without backup heater) | ºC | 60 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 50 | 52 | 56 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*410*840 | 1150*430*960 | 1150*430*960 | 1150*430*1400 |