Availability: | |
---|---|
Features:
Designed and widely applied for public pools
Fast return on investment
Heating&Cooling function
Corrosion proof titanium heat exchange Long life span
Multiple system protections-Safe and reliable operation
World brand compressor
Self-diagnosis-Displaying error code on control panel
Galvanized powered coated steel cabinet
HIGHER EFFICIENT: HEATING/COOLING
Anti-freezing Protection
Higher Efficient:Heating/Cooling
Air source heat pumps are a higher efficient solution for both heating and cooling needs in buildings. One of the key components that make them so effective is the 4 way valve, which allows the heat pump to switch between heating and cooling modes with ease. This valve works by reversing the flow of refrigerant, which allows the heat pump to extract heat from the air outside and transfer it inside during the heating season, and extract heat from inside and transfer it outside during the cooling season. By utilizing this technology, air source heat pumps can achieve higher efficiency levels compared to traditional heating and cooling systems.
Key Components
Swimming pool heat pumps that aim to meet the needs of aquatic facilities such as municipal authorities, hotels, sports arenas, resorts, and schools. This system utilizes cost-effective, environmentally friendly, and reliable air energy to heat swimming pools, providing benefits to all users. Compared to traditional electric pool heaters, this type of system is more efficient as it uses external air to regulate the temperature of the pool. Additionally, this system helps to reduce energy costs and carbon footprint of the facility.
Features:
Designed and widely applied for public pools
Fast return on investment
Heating&Cooling function
Corrosion proof titanium heat exchange Long life span
Multiple system protections-Safe and reliable operation
World brand compressor
Self-diagnosis-Displaying error code on control panel
Galvanized powered coated steel cabinet
HIGHER EFFICIENT: HEATING/COOLING
Anti-freezing Protection
Higher Efficient:Heating/Cooling
Air source heat pumps are a higher efficient solution for both heating and cooling needs in buildings. One of the key components that make them so effective is the 4 way valve, which allows the heat pump to switch between heating and cooling modes with ease. This valve works by reversing the flow of refrigerant, which allows the heat pump to extract heat from the air outside and transfer it inside during the heating season, and extract heat from inside and transfer it outside during the cooling season. By utilizing this technology, air source heat pumps can achieve higher efficiency levels compared to traditional heating and cooling systems.
Key Components
Swimming pool heat pumps that aim to meet the needs of aquatic facilities such as municipal authorities, hotels, sports arenas, resorts, and schools. This system utilizes cost-effective, environmentally friendly, and reliable air energy to heat swimming pools, providing benefits to all users. Compared to traditional electric pool heaters, this type of system is more efficient as it uses external air to regulate the temperature of the pool. Additionally, this system helps to reduce energy costs and carbon footprint of the facility.
CODE | WP31 | WP35 | WP45 | WP55 | WP80 | WP90 |
Advised pool size (m3) | 45~90 | 50~100 | 60~140 | 80~170 | 110~250 | 130~300 |
Heating Performance Condition: Air 24ºC, Water 26ºC | ||||||
Heating Capacity (KW) | 29.5 | 34.5 | 41.2 | 50.2 | 76.3 | 88.2 |
COP | 5.8 | 5.7 | 5.93 | 5.95 | 5.9 | 5.8 |
Heating Performance Condition: Air 15ºC, Water 26ºC | ||||||
Heating Capacity (KW) | 23.2 | 26.74 | 34.2 | 42.6 | 59.1 | 69.8 |
COP | 4.77 | 4.69 | 4.86 | 4.96 | 4.92 | 4.85 |
Operating Air Temperature ºC | -5~43 | |||||
Power Supply (V/Hz) | 380V/3PH/50HZ | |||||
Rated Input Power(KW) | 5.09 | 6.05 | 6.95 | 8.44 | 12.93 | 15.21 |
Rated Input Current(A) | 9.10 | 10.83 | 12.43 | 15.09 | 23.13 | 27.2 |
Max Heating Current (A) | 11.8 | 14.1 | 16.2 | 19.6 | 30.1 | 35.4 |
Water Flow Rate (m3/h) | 13.3 | 15 | 19.3 | 23.6 | 34.4 | 38.7 |
Water Connection ( inch) | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 |
Sound level at 1m (dB(A)) | 60 | 60 | 62 | 62 | 64 | 64 |
Net Dimension L*W*H(mm) | 700*660*960 | 1480*730*1070 | 1480*730*1270 | 1480*730*1270 | 2170*765*1300 | 2170*765*1300 |
Qty per 20ft/40HQ(PCS) | 48/96 | 10/44 | 10/22 | 10/22 | 6/14 | 6/14 |
Remarks:The Specifications are subject to changes without notice. |
CODE | WP31 | WP35 | WP45 | WP55 | WP80 | WP90 |
Advised pool size (m3) | 45~90 | 50~100 | 60~140 | 80~170 | 110~250 | 130~300 |
Heating Performance Condition: Air 24ºC, Water 26ºC | ||||||
Heating Capacity (KW) | 29.5 | 34.5 | 41.2 | 50.2 | 76.3 | 88.2 |
COP | 5.8 | 5.7 | 5.93 | 5.95 | 5.9 | 5.8 |
Heating Performance Condition: Air 15ºC, Water 26ºC | ||||||
Heating Capacity (KW) | 23.2 | 26.74 | 34.2 | 42.6 | 59.1 | 69.8 |
COP | 4.77 | 4.69 | 4.86 | 4.96 | 4.92 | 4.85 |
Operating Air Temperature ºC | -5~43 | |||||
Power Supply (V/Hz) | 380V/3PH/50HZ | |||||
Rated Input Power(KW) | 5.09 | 6.05 | 6.95 | 8.44 | 12.93 | 15.21 |
Rated Input Current(A) | 9.10 | 10.83 | 12.43 | 15.09 | 23.13 | 27.2 |
Max Heating Current (A) | 11.8 | 14.1 | 16.2 | 19.6 | 30.1 | 35.4 |
Water Flow Rate (m3/h) | 13.3 | 15 | 19.3 | 23.6 | 34.4 | 38.7 |
Water Connection ( inch) | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 |
Sound level at 1m (dB(A)) | 60 | 60 | 62 | 62 | 64 | 64 |
Net Dimension L*W*H(mm) | 700*660*960 | 1480*730*1070 | 1480*730*1270 | 1480*730*1270 | 2170*765*1300 | 2170*765*1300 |
Qty per 20ft/40HQ(PCS) | 48/96 | 10/44 | 10/22 | 10/22 | 6/14 | 6/14 |
Remarks:The Specifications are subject to changes without notice. |