Availability: | |
---|---|
Features:
DC inverter technology enables the heat pump to adjust its frequencyaccording to real heating requirement. With this technology, Wotech R290 air to water heat pump achieves an energy level of A+++ according to Erp directive.
R290 Green Gas at low GWP(3)
R290 is one of the best refrigerants available for mass production upto now: Negligible Global Warming Potential (GWP) and degradation time is considered in months: Zero ozone layer depletion potential (ODP): Permanent green: Less load for the same performance; Low energy consumption and higher efficiency.
Thanks to the use of R290, Wotech R290 air to water heat pump is now not only the best solution for new buildings, but also possible to fit the retrofit market by lifting up maximum heating temperature to 70°C. With good performance in this range of water temperatures, it is now possible to replace an old gas/oil boiler with an air-to-water heat pump unit without changing the existing heating distribution system or even the old radiators inside.
ENERGY EFFICIENCY RATING LABEL
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
Full Inerter Technology
With the inclusion of the Full DC Inverter technology, the Inventor heat pump operates at the ideal setting for the constantly changing consumption requirements, operating at the lowest possible noise level while conserving energy.
Two heating circuits [as standard]
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
DHW tank disinfection
The water inside the HWT (hot water tank) must be periodically heated to temperatures over 65°C to eliminate bacterial growth inside the tank if domestic hot water is provided directly from the tank.For healthy living, Wotech air source heat pump automatically controls this function based on parameter settings.
Climate curve
Air source heat pumps extract thermal energy (heat) from the outside air and convert this into heating and hotwater for your home. Air source heat pumps are designed to work in cold temperatures and are suitable for arange of homes, from a small apartment to a large detached home. Air source heat pumps do require electricity to operate, but 75% of the energy required is generated from the outside air, with only 25% being required fromelectricity. This means that 75% of the energy you use will be from a renewable source, which will reduce youremissions and CO2 impact
Air source heat pump
The air source heat pump draws free energy from the air and uses it to heat and cool the building or prepare domestic hot water. It's a cheap, eco-friendly and reliable heat source that anyone can use.
Thanks to cutting-edge technology, Wotech heat pumps operate at a wide range of external temperatures and achieve the high temperature parameters of heating systems or domestic hot water. The emission of no hazardous materials into the environment, operational safety and no maintenance make the Wotech heat pump an ideal solution for everyone building a home and replacing or retrofitting a current heat source..Wotech heat pumps are available for single-family, multifamily and commercial buildings.
Features:
DC inverter technology enables the heat pump to adjust its frequencyaccording to real heating requirement. With this technology, Wotech R290 air to water heat pump achieves an energy level of A+++ according to Erp directive.
R290 Green Gas at low GWP(3)
R290 is one of the best refrigerants available for mass production upto now: Negligible Global Warming Potential (GWP) and degradation time is considered in months: Zero ozone layer depletion potential (ODP): Permanent green: Less load for the same performance; Low energy consumption and higher efficiency.
Thanks to the use of R290, Wotech R290 air to water heat pump is now not only the best solution for new buildings, but also possible to fit the retrofit market by lifting up maximum heating temperature to 70°C. With good performance in this range of water temperatures, it is now possible to replace an old gas/oil boiler with an air-to-water heat pump unit without changing the existing heating distribution system or even the old radiators inside.
ENERGY EFFICIENCY RATING LABEL
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
Full Inerter Technology
With the inclusion of the Full DC Inverter technology, the Inventor heat pump operates at the ideal setting for the constantly changing consumption requirements, operating at the lowest possible noise level while conserving energy.
Two heating circuits [as standard]
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
DHW tank disinfection
The water inside the HWT (hot water tank) must be periodically heated to temperatures over 65°C to eliminate bacterial growth inside the tank if domestic hot water is provided directly from the tank.For healthy living, Wotech air source heat pump automatically controls this function based on parameter settings.
Climate curve
Air source heat pumps extract thermal energy (heat) from the outside air and convert this into heating and hotwater for your home. Air source heat pumps are designed to work in cold temperatures and are suitable for arange of homes, from a small apartment to a large detached home. Air source heat pumps do require electricity to operate, but 75% of the energy required is generated from the outside air, with only 25% being required fromelectricity. This means that 75% of the energy you use will be from a renewable source, which will reduce youremissions and CO2 impact
Air source heat pump
The air source heat pump draws free energy from the air and uses it to heat and cool the building or prepare domestic hot water. It's a cheap, eco-friendly and reliable heat source that anyone can use.
Thanks to cutting-edge technology, Wotech heat pumps operate at a wide range of external temperatures and achieve the high temperature parameters of heating systems or domestic hot water. The emission of no hazardous materials into the environment, operational safety and no maintenance make the Wotech heat pump an ideal solution for everyone building a home and replacing or retrofitting a current heat source..Wotech heat pumps are available for single-family, multifamily and commercial buildings.
Market model | WW05VM | WW09VM | WW15VM | WW20VT | |||||
Heating | Output Capacity | Kw | 1.89-4.80 | 3.62-9.20 | 5.89-14.96 | 8.03-20.38 | |||
Input Power | Kw | 0.36-1.09 | 0.71-2.19 | 1.21-3.72 | 1.53-4.70 | ||||
COP | - | 4.39-5.62 | 4.19-5.07 | 4.02-4.86 | 4.34-5.25 | ||||
Input Current | A | 1.64-5.01 | 3.27-10.04 | 5.55-17.04 | 2.60-7.99 | ||||
Heating | Output Capacity | Kw | 1.68-4.43 | 3.21-8.45 | 5.56-14.87 | 7.23-19.02 | |||
Input Power | Kw | 0.58-1.81 | 0.99-3.06 | 1.83-5.68 | 2.08-6.44 | ||||
COP | - | 2.45-2.89 | 2.76-3.26 | 2.62-3.09 | 2.95-3.48 | ||||
Input Current | A | 2.67-8.28 | 4.51-14.01 | 8.36-25.98 | 3.54-10.98 | ||||
Heating | Output Capacity | Kw | 2.30-5.76 | 4.49-11.22 | 7.24-18.10 | 9.78-24.46 | |||
Input Power | Kw | 0.46-1.36 | 0.94-2.75 | 1.58-4.63 | 1.98-5.80 | ||||
COP | - | 4.24-4.96 | 4.08-4.77 | 3.91-4.57 | 4.22-4.94 | ||||
Input Current | A | 2.13-6.22 | 4.30-12.59 | 7.24-21.19 | 3.37-9.86 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 1.48-3.53 | 2.95-7.03 | 3.91-9.30 | 5.63-13.41 | |||
Input Power | Kw | 0.50-1.41 | 0.98-2.76 | 1.46-4.10 | 1.89-5.32 | ||||
EER | - | 2.51-2.96 | 2.55-3.01 | 2.27-2.67 | 2.52-2.97 | ||||
Input Current | A | 2.29-6.44 | 4.49-12.62 | 6.69-18.79 | 3.22-9.05 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R290 | |||||||
Max Water Temperature(without backup heater) | ºC | 75 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 49 | 50 | 53 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*440*840 | 1085*440*840 | 1150*430*960 | 1150*430*1400 |
Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825
Market model | WW05VM | WW09VM | WW15VM | WW20VT | |||||
Heating | Output Capacity | Kw | 1.89-4.80 | 3.62-9.20 | 5.89-14.96 | 8.03-20.38 | |||
Input Power | Kw | 0.36-1.09 | 0.71-2.19 | 1.21-3.72 | 1.53-4.70 | ||||
COP | - | 4.39-5.62 | 4.19-5.07 | 4.02-4.86 | 4.34-5.25 | ||||
Input Current | A | 1.64-5.01 | 3.27-10.04 | 5.55-17.04 | 2.60-7.99 | ||||
Heating | Output Capacity | Kw | 1.68-4.43 | 3.21-8.45 | 5.56-14.87 | 7.23-19.02 | |||
Input Power | Kw | 0.58-1.81 | 0.99-3.06 | 1.83-5.68 | 2.08-6.44 | ||||
COP | - | 2.45-2.89 | 2.76-3.26 | 2.62-3.09 | 2.95-3.48 | ||||
Input Current | A | 2.67-8.28 | 4.51-14.01 | 8.36-25.98 | 3.54-10.98 | ||||
Heating | Output Capacity | Kw | 2.30-5.76 | 4.49-11.22 | 7.24-18.10 | 9.78-24.46 | |||
Input Power | Kw | 0.46-1.36 | 0.94-2.75 | 1.58-4.63 | 1.98-5.80 | ||||
COP | - | 4.24-4.96 | 4.08-4.77 | 3.91-4.57 | 4.22-4.94 | ||||
Input Current | A | 2.13-6.22 | 4.30-12.59 | 7.24-21.19 | 3.37-9.86 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 1.48-3.53 | 2.95-7.03 | 3.91-9.30 | 5.63-13.41 | |||
Input Power | Kw | 0.50-1.41 | 0.98-2.76 | 1.46-4.10 | 1.89-5.32 | ||||
EER | - | 2.51-2.96 | 2.55-3.01 | 2.27-2.67 | 2.52-2.97 | ||||
Input Current | A | 2.29-6.44 | 4.49-12.62 | 6.69-18.79 | 3.22-9.05 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R290 | |||||||
Max Water Temperature(without backup heater) | ºC | 75 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 49 | 50 | 53 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*440*840 | 1085*440*840 | 1150*430*960 | 1150*430*1400 |
Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825