Features:
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
R290 Green Gas at low GWP(3)
To reduce carbon emissions to the environment and curb global warming, Wotech developed the R290 air-to-water heat pump. With many advantages such as low carbon emissions and high efficiency, the R290 refrigerant is recognized as the refrigerant with the most potential for development in the industry, contributing to the reduction of carbon emissions and helping to achieve the global goal of carbon neutrality.
ENERGY EFFICIENCY RATING LABEL
Wotech Air Source Heat Pump incorporates a high-efficiency compressor, a completely new high-efficiency heat exchange system, high-precision electronic expansion valves and other accessories. COP has met national level energy efficiency standards and received national energy efficiency certification.
Full Inerter Technology
The inverter technology in the Wotech heat pump reduces power consumption, which is related to the reduction of room cooling and heating costs. Its use translates to the quiet operation of the unit and faster achievement of the desired temperature.
Two heating circuits [as standard]
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
DHW tank disinfection
By heating the water in the system to 65°C, the high temperature kills most bacteria (including Legionella).
Climate curve
Using proprietary Heating Curve Logic, users can set up the system to meet their optimum comfort levels based on the changing heat demand,insulation levels, etc Wotech air to water heat pump can adjust the outlet water temperatures based on the ambient temperature,by continually monitoring and adjusting it in opposite direction with the current ambient temperature levels to ensure the optimum comfort in the living spaces
Air to water heat pump
Wotech air to water Heat Pump for residential and commercial applications. Offering capacities from 5kW all the way up to 30kW, this ensures a system that will work regardless of your heating and cooling needs. Suitable for new build and refurbishment projects, the solutions are cost-effective with minimised environmental impact.
Features:
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
R290 Green Gas at low GWP(3)
To reduce carbon emissions to the environment and curb global warming, Wotech developed the R290 air-to-water heat pump. With many advantages such as low carbon emissions and high efficiency, the R290 refrigerant is recognized as the refrigerant with the most potential for development in the industry, contributing to the reduction of carbon emissions and helping to achieve the global goal of carbon neutrality.
ENERGY EFFICIENCY RATING LABEL
Wotech Air Source Heat Pump incorporates a high-efficiency compressor, a completely new high-efficiency heat exchange system, high-precision electronic expansion valves and other accessories. COP has met national level energy efficiency standards and received national energy efficiency certification.
Full Inerter Technology
The inverter technology in the Wotech heat pump reduces power consumption, which is related to the reduction of room cooling and heating costs. Its use translates to the quiet operation of the unit and faster achievement of the desired temperature.
Two heating circuits [as standard]
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
DHW tank disinfection
By heating the water in the system to 65°C, the high temperature kills most bacteria (including Legionella).
Climate curve
Using proprietary Heating Curve Logic, users can set up the system to meet their optimum comfort levels based on the changing heat demand,insulation levels, etc Wotech air to water heat pump can adjust the outlet water temperatures based on the ambient temperature,by continually monitoring and adjusting it in opposite direction with the current ambient temperature levels to ensure the optimum comfort in the living spaces
Air to water heat pump
Wotech air to water Heat Pump for residential and commercial applications. Offering capacities from 5kW all the way up to 30kW, this ensures a system that will work regardless of your heating and cooling needs. Suitable for new build and refurbishment projects, the solutions are cost-effective with minimised environmental impact.
Market model | WW05VM | WW09VM | WW15VM | WW20VT | |||||
Heating | Output Capacity | Kw | 1.89-4.80 | 3.62-9.20 | 5.89-14.96 | 8.03-20.38 | |||
Input Power | Kw | 0.36-1.09 | 0.71-2.19 | 1.21-3.72 | 1.53-4.70 | ||||
COP | - | 4.39-5.62 | 4.19-5.07 | 4.02-4.86 | 4.34-5.25 | ||||
Input Current | A | 1.64-5.01 | 3.27-10.04 | 5.55-17.04 | 2.60-7.99 | ||||
Heating | Output Capacity | Kw | 1.68-4.43 | 3.21-8.45 | 5.56-14.87 | 7.23-19.02 | |||
Input Power | Kw | 0.58-1.81 | 0.99-3.06 | 1.83-5.68 | 2.08-6.44 | ||||
COP | - | 2.45-2.89 | 2.76-3.26 | 2.62-3.09 | 2.95-3.48 | ||||
Input Current | A | 2.67-8.28 | 4.51-14.01 | 8.36-25.98 | 3.54-10.98 | ||||
Heating | Output Capacity | Kw | 2.30-5.76 | 4.49-11.22 | 7.24-18.10 | 9.78-24.46 | |||
Input Power | Kw | 0.46-1.36 | 0.94-2.75 | 1.58-4.63 | 1.98-5.80 | ||||
COP | - | 4.24-4.96 | 4.08-4.77 | 3.91-4.57 | 4.22-4.94 | ||||
Input Current | A | 2.13-6.22 | 4.30-12.59 | 7.24-21.19 | 3.37-9.86 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 1.48-3.53 | 2.95-7.03 | 3.91-9.30 | 5.63-13.41 | |||
Input Power | Kw | 0.50-1.41 | 0.98-2.76 | 1.46-4.10 | 1.89-5.32 | ||||
EER | - | 2.51-2.96 | 2.55-3.01 | 2.27-2.67 | 2.52-2.97 | ||||
Input Current | A | 2.29-6.44 | 4.49-12.62 | 6.69-18.79 | 3.22-9.05 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R290 | |||||||
Max Water Temperature(without backup heater) | ºC | 75 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 49 | 50 | 53 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*440*840 | 1085*440*840 | 1150*430*960 | 1150*430*1400 |
Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825
Market model | WW05VM | WW09VM | WW15VM | WW20VT | |||||
Heating | Output Capacity | Kw | 1.89-4.80 | 3.62-9.20 | 5.89-14.96 | 8.03-20.38 | |||
Input Power | Kw | 0.36-1.09 | 0.71-2.19 | 1.21-3.72 | 1.53-4.70 | ||||
COP | - | 4.39-5.62 | 4.19-5.07 | 4.02-4.86 | 4.34-5.25 | ||||
Input Current | A | 1.64-5.01 | 3.27-10.04 | 5.55-17.04 | 2.60-7.99 | ||||
Heating | Output Capacity | Kw | 1.68-4.43 | 3.21-8.45 | 5.56-14.87 | 7.23-19.02 | |||
Input Power | Kw | 0.58-1.81 | 0.99-3.06 | 1.83-5.68 | 2.08-6.44 | ||||
COP | - | 2.45-2.89 | 2.76-3.26 | 2.62-3.09 | 2.95-3.48 | ||||
Input Current | A | 2.67-8.28 | 4.51-14.01 | 8.36-25.98 | 3.54-10.98 | ||||
Heating | Output Capacity | Kw | 2.30-5.76 | 4.49-11.22 | 7.24-18.10 | 9.78-24.46 | |||
Input Power | Kw | 0.46-1.36 | 0.94-2.75 | 1.58-4.63 | 1.98-5.80 | ||||
COP | - | 4.24-4.96 | 4.08-4.77 | 3.91-4.57 | 4.22-4.94 | ||||
Input Current | A | 2.13-6.22 | 4.30-12.59 | 7.24-21.19 | 3.37-9.86 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 1.48-3.53 | 2.95-7.03 | 3.91-9.30 | 5.63-13.41 | |||
Input Power | Kw | 0.50-1.41 | 0.98-2.76 | 1.46-4.10 | 1.89-5.32 | ||||
EER | - | 2.51-2.96 | 2.55-3.01 | 2.27-2.67 | 2.52-2.97 | ||||
Input Current | A | 2.29-6.44 | 4.49-12.62 | 6.69-18.79 | 3.22-9.05 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R290 | |||||||
Max Water Temperature(without backup heater) | ºC | 75 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 49 | 50 | 53 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*440*840 | 1085*440*840 | 1150*430*960 | 1150*430*1400 |
Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825