In the monoblock type heat pump, the refrigerant system is completely integrated in the external unit. Such a solution ensures, above all, good thermal insulation, space saving and quiet operation of the device. In addition, the compact design ensures easy installation and simple maintenance.
R32 Gas-Low GWP
Good SCOP,energy label rating W35℃ A+++/ W55℃ A++
Smart logic to control multiple heat source
Climate curves suitable for different countries
House heating,cooling and domestic hot water
Full inverter system,Stable and efficient performance.
Air source heat pumps using R32 refrigerants can not only improve the efficiency and energy utilization of equipment, but also help reduce damage to the atmosphere, making them more environmentally friendly.
Space heating Series is specially developed with the most cutting-edge heat pump technology and modern design to meet stringent requirements for efficiency, stability and quietness. Not only does Space heating Series use R32 green gas, but also is rated with A+++ energy label. With top energy rating A+++, the unit is energy efficient and can greatly reduce energy bills for users.
We choose MITSUBISHI compressor for the heat pump. It ensures stable working in the perfect performance.
Smart design to work with other heating facilities in your house, like solar, gas boiler and etc, make sure you to pay the lowest bill for heating !
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
The DHW tank disinfection function is used to kill legionella by 65°C
water to ensure the health and safety.
You can choose different climate correlation curves or your own
customised curve. Once the curve is selected, the unit sets the outlet water temperature automatically according to the outdoor ambient air temperature.
Protect your home floor by activating the Floor Preheating function which slowly increases the heating temperature of the floor coils, avoiding possible floor damaging and transitioning smoothly to the heating function. The Floor Drying Up function provides an additional solution to the installer as it helps remove any residual moisture from newly installed floor coils, further protecting the installation and ensuring the optimal and effective operation of the heat pump.
In the monoblock type heat pump, the refrigerant system is completely integrated in the external unit. Such a solution ensures, above all, good thermal insulation, space saving and quiet operation of the device. In addition, the compact design ensures easy installation and simple maintenance.
R32 Gas-Low GWP
Good SCOP,energy label rating W35℃ A+++/ W55℃ A++
Smart logic to control multiple heat source
Climate curves suitable for different countries
House heating,cooling and domestic hot water
Full inverter system,Stable and efficient performance.
Air source heat pumps using R32 refrigerants can not only improve the efficiency and energy utilization of equipment, but also help reduce damage to the atmosphere, making them more environmentally friendly.
Space heating Series is specially developed with the most cutting-edge heat pump technology and modern design to meet stringent requirements for efficiency, stability and quietness. Not only does Space heating Series use R32 green gas, but also is rated with A+++ energy label. With top energy rating A+++, the unit is energy efficient and can greatly reduce energy bills for users.
We choose MITSUBISHI compressor for the heat pump. It ensures stable working in the perfect performance.
Smart design to work with other heating facilities in your house, like solar, gas boiler and etc, make sure you to pay the lowest bill for heating !
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
The DHW tank disinfection function is used to kill legionella by 65°C
water to ensure the health and safety.
You can choose different climate correlation curves or your own
customised curve. Once the curve is selected, the unit sets the outlet water temperature automatically according to the outdoor ambient air temperature.
Protect your home floor by activating the Floor Preheating function which slowly increases the heating temperature of the floor coils, avoiding possible floor damaging and transitioning smoothly to the heating function. The Floor Drying Up function provides an additional solution to the installer as it helps remove any residual moisture from newly installed floor coils, further protecting the installation and ensuring the optimal and effective operation of the heat pump.
Market model | WW08VM | WW12VM | WW16VM | WW20VT | |||||
Heating | Output Capacity | Kw | 4.78-12.13 | 4.78-12.13 | 6.58-16.71 | 8.14-20.67 | |||
Input Power | Kw | 0.58-1.75 | 0.89-2.75 | 1.21-3.72 | 1.45-4.24 | ||||
COP | - | 4.68-5.62 | 4.42-5.35 | 4.49-5.43 | 4.87-5.60 | ||||
Input Current | A | 2.63-8.01 | 4.09-12.59 | 5.54-17.03 | 2.47-7.21 | ||||
Heating | Output Capacity | Kw | 2.73-7.19 | 4.16-10.94 | 5.54-14.57 | 7.41-19.50 | |||
Input Power | Kw | 0.96-2.51 | 1.35-4.19 | 1.68-5.20 | 1.95-6.06 | ||||
COP | - | 2.86-3.37 | 2.61-3.08 | 2.80-3.30 | 3.22-3.80 | ||||
Input Current | A | 4.37-11.50 | 6.18-19.18 | 7.67-23.81 | 3.32-10.30 | ||||
Heating | Output Capacity | Kw | 3.88-9.84 | 5.73-14.56 | 7.90-20.05 | 9.77-24.80 | |||
Input Power | Kw | 0.80-2.23 | 1.23-3.42 | 1.69-4.71 | 2.04-5.70 | ||||
COP | - | 4.42-4.86 | 4.25-4.68 | 4.26-4.69 | 4.35-4.79 | ||||
Input Current | A | 3.65-10.19 | 5.61-15.67 | 7.71-21.54 | 3.47-9.70 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 2.74-6.53 | 4.07-9.70 | 5.28-12.58 | 6.57-15.65 | |||
Input Power | Kw | 0.88-2.48 | 1.30-3.66 | 1.59-4.48 | 1.99-5.20 | ||||
EER | - | 2.63-3.10 | 2.65-3.13 | 2.81-3.32 | 3.01-3.31 | ||||
Input Current | A | 4.04-11.35 | 5.96-16.75 | 7.29-20.49 | 3.38-8.84 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R32 | |||||||
Max Water Temperature(without backup heater) | ºC | 60 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 50 | 52 | 56 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*410*840 | 1150*430*960 | 1150*430*960 | 1150*430*1400 |
Market model | WW08VM | WW12VM | WW16VM | WW20VT | |||||
Heating | Output Capacity | Kw | 4.78-12.13 | 4.78-12.13 | 6.58-16.71 | 8.14-20.67 | |||
Input Power | Kw | 0.58-1.75 | 0.89-2.75 | 1.21-3.72 | 1.45-4.24 | ||||
COP | - | 4.68-5.62 | 4.42-5.35 | 4.49-5.43 | 4.87-5.60 | ||||
Input Current | A | 2.63-8.01 | 4.09-12.59 | 5.54-17.03 | 2.47-7.21 | ||||
Heating | Output Capacity | Kw | 2.73-7.19 | 4.16-10.94 | 5.54-14.57 | 7.41-19.50 | |||
Input Power | Kw | 0.96-2.51 | 1.35-4.19 | 1.68-5.20 | 1.95-6.06 | ||||
COP | - | 2.86-3.37 | 2.61-3.08 | 2.80-3.30 | 3.22-3.80 | ||||
Input Current | A | 4.37-11.50 | 6.18-19.18 | 7.67-23.81 | 3.32-10.30 | ||||
Heating | Output Capacity | Kw | 3.88-9.84 | 5.73-14.56 | 7.90-20.05 | 9.77-24.80 | |||
Input Power | Kw | 0.80-2.23 | 1.23-3.42 | 1.69-4.71 | 2.04-5.70 | ||||
COP | - | 4.42-4.86 | 4.25-4.68 | 4.26-4.69 | 4.35-4.79 | ||||
Input Current | A | 3.65-10.19 | 5.61-15.67 | 7.71-21.54 | 3.47-9.70 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 2.74-6.53 | 4.07-9.70 | 5.28-12.58 | 6.57-15.65 | |||
Input Power | Kw | 0.88-2.48 | 1.30-3.66 | 1.59-4.48 | 1.99-5.20 | ||||
EER | - | 2.63-3.10 | 2.65-3.13 | 2.81-3.32 | 3.01-3.31 | ||||
Input Current | A | 4.04-11.35 | 5.96-16.75 | 7.29-20.49 | 3.38-8.84 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R32 | |||||||
Max Water Temperature(without backup heater) | ºC | 60 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 50 | 52 | 56 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*410*840 | 1150*430*960 | 1150*430*960 | 1150*430*1400 |