R290 Green Gas at low GWP(3)
Good SCOP,energy label rating W35℃ A+++/ W55℃ A++
Smart logic to control multiple heat source
Climate curves suitable for different countries
Hot water up to 75C,suitable for underfloor/radiator heating/fan coil
Full inverter system,Stable and efficient performance.
R290 is one of the best refrigerant available for mass production upto now:Negligible Global Warming Potential(GWP) and degradation time is considered in monthes;
Zero ozone layer depletion potential(ODP);
Permanent green;
Less load for the same performance;
Low energy consumption and higher efficiency.
Space heating Series is specially developed with the most cutting-edge heat pump technology and modern design to meet stringent requirements for efficiency, stability and quietness. Not only does Space heating Series use R290 green gas, but also is rated with A+++ energy label. With top energy rating A+++, the unit is energy efficient and can greatly reduce energy bills for users.
Smart design to work with other heating facilities in your house, like solar, gas boiler and etc, make sure you to pay the lowest bill for heating !
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
Protect your home floor by activating the Floor Preheating function which
slowly increases the heating temperature of the floor coils, avoiding
possible floor damaging and transitioning smoothly to the heating function. The Floor Drying Up function provides an additional solution to
the installer as it helps remove any residual moisture from newly installed
floor coils, further protecting the installation and ensuring the optimal and effective operation of the heat pump.
Eco mode is an intelligent energy-saving mode that can minimize energy consumption while ensuring comfortable temperatures, achieving green environmental protection for air source heat pumps.
By heating the water in the system to 65°C, the high temperature kills most bacteria (including Legionella).
R290 Green Gas at low GWP(3)
Good SCOP,energy label rating W35℃ A+++/ W55℃ A++
Smart logic to control multiple heat source
Climate curves suitable for different countries
Hot water up to 75C,suitable for underfloor/radiator heating/fan coil
Full inverter system,Stable and efficient performance.
R290 is one of the best refrigerant available for mass production upto now:Negligible Global Warming Potential(GWP) and degradation time is considered in monthes;
Zero ozone layer depletion potential(ODP);
Permanent green;
Less load for the same performance;
Low energy consumption and higher efficiency.
Space heating Series is specially developed with the most cutting-edge heat pump technology and modern design to meet stringent requirements for efficiency, stability and quietness. Not only does Space heating Series use R290 green gas, but also is rated with A+++ energy label. With top energy rating A+++, the unit is energy efficient and can greatly reduce energy bills for users.
Smart design to work with other heating facilities in your house, like solar, gas boiler and etc, make sure you to pay the lowest bill for heating !
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
Protect your home floor by activating the Floor Preheating function which
slowly increases the heating temperature of the floor coils, avoiding
possible floor damaging and transitioning smoothly to the heating function. The Floor Drying Up function provides an additional solution to
the installer as it helps remove any residual moisture from newly installed
floor coils, further protecting the installation and ensuring the optimal and effective operation of the heat pump.
Eco mode is an intelligent energy-saving mode that can minimize energy consumption while ensuring comfortable temperatures, achieving green environmental protection for air source heat pumps.
By heating the water in the system to 65°C, the high temperature kills most bacteria (including Legionella).
Market model | WW05VM | WW09VM | WW15VM | WW20VT | |||||
Heating | Output Capacity | Kw | 1.89-4.80 | 3.62-9.20 | 5.89-14.96 | 8.03-20.38 | |||
Input Power | Kw | 0.36-1.09 | 0.71-2.19 | 1.21-3.72 | 1.53-4.70 | ||||
COP | - | 4.39-5.62 | 4.19-5.07 | 4.02-4.86 | 4.34-5.25 | ||||
Input Current | A | 1.64-5.01 | 3.27-10.04 | 5.55-17.04 | 2.60-7.99 | ||||
Heating | Output Capacity | Kw | 1.68-4.43 | 3.21-8.45 | 5.56-14.87 | 7.23-19.02 | |||
Input Power | Kw | 0.58-1.81 | 0.99-3.06 | 1.83-5.68 | 2.08-6.44 | ||||
COP | - | 2.45-2.89 | 2.76-3.26 | 2.62-3.09 | 2.95-3.48 | ||||
Input Current | A | 2.67-8.28 | 4.51-14.01 | 8.36-25.98 | 3.54-10.98 | ||||
Heating | Output Capacity | Kw | 2.30-5.76 | 4.49-11.22 | 7.24-18.10 | 9.78-24.46 | |||
Input Power | Kw | 0.46-1.36 | 0.94-2.75 | 1.58-4.63 | 1.98-5.80 | ||||
COP | - | 4.24-4.96 | 4.08-4.77 | 3.91-4.57 | 4.22-4.94 | ||||
Input Current | A | 2.13-6.22 | 4.30-12.59 | 7.24-21.19 | 3.37-9.86 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 1.48-3.53 | 2.95-7.03 | 3.91-9.30 | 5.63-13.41 | |||
Input Power | Kw | 0.50-1.41 | 0.98-2.76 | 1.46-4.10 | 1.89-5.32 | ||||
EER | - | 2.51-2.96 | 2.55-3.01 | 2.27-2.67 | 2.52-2.97 | ||||
Input Current | A | 2.29-6.44 | 4.49-12.62 | 6.69-18.79 | 3.22-9.05 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R290 | |||||||
Max Water Temperature(without backup heater) | ºC | 75 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 49 | 50 | 53 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*440*840 | 1085*440*840 | 1150*430*960 | 1150*430*1400 |
Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825
Market model | WW05VM | WW09VM | WW15VM | WW20VT | |||||
Heating | Output Capacity | Kw | 1.89-4.80 | 3.62-9.20 | 5.89-14.96 | 8.03-20.38 | |||
Input Power | Kw | 0.36-1.09 | 0.71-2.19 | 1.21-3.72 | 1.53-4.70 | ||||
COP | - | 4.39-5.62 | 4.19-5.07 | 4.02-4.86 | 4.34-5.25 | ||||
Input Current | A | 1.64-5.01 | 3.27-10.04 | 5.55-17.04 | 2.60-7.99 | ||||
Heating | Output Capacity | Kw | 1.68-4.43 | 3.21-8.45 | 5.56-14.87 | 7.23-19.02 | |||
Input Power | Kw | 0.58-1.81 | 0.99-3.06 | 1.83-5.68 | 2.08-6.44 | ||||
COP | - | 2.45-2.89 | 2.76-3.26 | 2.62-3.09 | 2.95-3.48 | ||||
Input Current | A | 2.67-8.28 | 4.51-14.01 | 8.36-25.98 | 3.54-10.98 | ||||
Heating | Output Capacity | Kw | 2.30-5.76 | 4.49-11.22 | 7.24-18.10 | 9.78-24.46 | |||
Input Power | Kw | 0.46-1.36 | 0.94-2.75 | 1.58-4.63 | 1.98-5.80 | ||||
COP | - | 4.24-4.96 | 4.08-4.77 | 3.91-4.57 | 4.22-4.94 | ||||
Input Current | A | 2.13-6.22 | 4.30-12.59 | 7.24-21.19 | 3.37-9.86 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 1.48-3.53 | 2.95-7.03 | 3.91-9.30 | 5.63-13.41 | |||
Input Power | Kw | 0.50-1.41 | 0.98-2.76 | 1.46-4.10 | 1.89-5.32 | ||||
EER | - | 2.51-2.96 | 2.55-3.01 | 2.27-2.67 | 2.52-2.97 | ||||
Input Current | A | 2.29-6.44 | 4.49-12.62 | 6.69-18.79 | 3.22-9.05 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R290 | |||||||
Max Water Temperature(without backup heater) | ºC | 75 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 49 | 50 | 53 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*440*840 | 1085*440*840 | 1150*430*960 | 1150*430*1400 |
Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825